57B+
90% range 52.5–61.8
Angelini & Associates Architects
Primary kind of workMixed / general
activefeaturedhigh confidence
Sub-scores
Inspections61
better than peers
Failed / re-inspection results on 15% of inspections vs 25% expected for similar jobs
Plan quality / Revisions54
typical
0.97 plan send-backs / revision events per permit vs 1.19 expected for similar jobs
Time to permit46
typical
Median 14.5 days to approval vs 16 days peer median (1.19× after adjusting for kind of work)
Completion43
worse than peers
22% of issued permits expired/voided without final vs 16% expected
More: compliance & reliability
Compliance73
better than peers
0.02 license/insurance/stop-work type holds per permit vs 0.09 expected
Reliability44
worse than peers
9% of inspections cancelled vs 7% expected
Ann Arbor activity & plain stats
Permits in scored set
63
Last 3 years
14
Last 12 months
4
Years active
16
2011–2026
Median days to approval
14.5
peer median 16.0
Permits needing a revision
43%
Permits with a failed / re-inspection
43%
Inspections on record
274
Job mix
Commercial alterations 27% Remodels 22% Additions / ADUs 17% Windows & doors 11% Decks & porches 8% New homes 5% Foundation / structural 3% Garages & accessory 2% Commercial new 2% Solar / EV 2% Siding / envelope 2%
Score by kind of work
Commercial alterations · 17 permits
52
Remodels · 14 permits
54
Additions / ADUs · 11 permits
50
Windows & doors · 7 permits
60
Decks & porches · 5 permits
56
Sample permit records
| Permit | Kind of work | Applied | Status | Days to approval | Notes |
|---|---|---|---|---|---|
| BLDGR24-0074 | Additions / ADUs | 2024-01-18 | Expired | 48 | inspection Footing [BLD]: Partial Pass inspection Insulation [BLD]: Partial Pass inspection Rough-In [BLD]: Partial Pass |
| BLDG20-0538 | Commercial alterations | 2020-03-26 | FINALED | 26 | inspection FOOTING: FAILED inspection COMPACTION: FAILED inspection FOUNDATION/REBAR: CONDITIONAL APPROVAL inspection COMPACTION: CONDITIONAL APPROVAL inspection **FINAL: PARTIAL PASS inspection **FINAL: FAILED |
| BLDG14-0939 | Commercial alterations | 2014-06-05 | FINALED | 26 | inspection **FINAL: FAILED inspection ABOVE CEILING/GRID: FAILED inspection ROUGH: CONDITIONAL APPROVAL revision review: APPROVED |
| BLDG13-0284 | Commercial alterations | 2013-03-01 | FINALED | 11 | — |
| BLDG12-0887 | Additions / ADUs | 2012-05-25 | FINALED | 9 | — |
| BLDG11-2180 | Commercial alterations | 2011-11-21 | FINALED | 6 | — |
Related Mixed / general firms
58B+
Composition Workshop INC
Mixed / general work
activemedium confidence
57B+
Edwin R. Wier, Architect
Mixed / general work
activefeaturedhigh confidence
60A−
Robert Darvas Associates
Mixed / general work
occasionalhigh confidence
53B−
Wagner Engineering, LLC
Mixed / general work
activefeaturedmedium confidence
62A−
LDA Consultants
Mixed / general work
activefeaturedhigh confidence