47C
90% range 43.3–51.7
Fonson Company Inc.
Primary kind of workMixed / general
activefeaturedmedium confidence
Sub-scores
Inspections36
worse than peers
Failed / re-inspection results on 40% of inspections vs 20% expected for similar jobs
Plan quality / Revisions57
better than peers
1.26 plan send-backs / revision events per permit vs 1.97 expected for similar jobs
Time to permit57
better than peers
Median 30 days to approval vs 29 days peer median (0.64× after adjusting for kind of work)
Completion51
typical
13% of issued permits expired/voided without final vs 14% expected
More: compliance & reliability
Compliance42
worse than peers
0.26 license/insurance/stop-work type holds per permit vs 0.16 expected
Reliability51
typical
6% of inspections cancelled vs 6% expected
Ann Arbor activity & plain stats
Permits in scored set
12
Last 3 years
8
Last 12 months
7
Years active
3
2022–2026
Median days to approval
30
peer median 29.0
Permits needing a revision
83%
Permits with a failed / re-inspection
50%
Inspections on record
43
Job mix
Commercial new 33% Garages & accessory 17% Additions / ADUs 17% Decks & porches 17% Commercial alterations 8% Foundation / structural 8%
Sample permit records
| Permit | Kind of work | Applied | Status | Days to approval | Notes |
|---|---|---|---|---|---|
| BLDGR26-0872 | Foundation / structural | 2026-06-01 | Final | 30 | inspection Backfill [BLD]: Re-inspection required inspection Drainage Connection [BLD]: Re-inspection required inspection Insulation [BLD]: Re-inspection required plan submittal v1 requires re-submit plan submittal v2 requires re-submit 2 eReview file(s) sent back for resubmittal |
| BLDGR23-2252 | Additions / ADUs | 2023-11-15 | Final | 49 | inspection Rough-In [BLD]: Partial Pass plan submittal v2 requires re-submit plan submittal v3 requires re-submit plan submittal v1 requires re-submit 6 eReview file(s) sent back for resubmittal |
| BLDGC26-0385 | Commercial new | 2026-07-10 | Issued | 24 | inspection Compaction [BLD]: Re-inspection required inspection Footing [BLD]: Re-inspection required inspection Foundation/Rebar [BLD]: Re-inspection required inspection Rough-In [BLD]: Re-inspection required 1 eReview file(s) sent back for resubmittal |
| BLDGC26-0312 | Commercial new | 2026-06-17 | Withdrawn | — | Permit placed on hold for more information |
| BLDGR23-0906 | Additions / ADUs | 2023-05-02 | Fees Due | — | — |
| BLDGC26-0310 | Commercial alterations | 2026-06-16 | Void - Wrong Workclass | — | — |
Related Mixed / general firms
47C
Miller Building LLC
Mixed / general work
activefeaturedhigh confidence
47C
Summit Homebuilding LLC
Mixed / general work
activefeaturedhigh confidence
47C
Main Street Homes
Mixed / general work
activefeaturedmedium confidence
47C
Nick of time construction
Mixed / general work
occasionallow confidence
48C+
Ash Woelke
Mixed / general work
occasionalmedium confidence