Ann Arbor Permit Report Cards

← All ratings

46
90% range 44.2–51.3

Alanis Construction

General Contractor · Ann Arbor, MI · #368 of 440 listed overall
Primary kind of workMixed / generalNo single kind of work is 50%+ of all permits · #82 of 100 mixed / general firms
activefeaturedhigh confidence

Overall score: 50 = peer average for the same role and the same kind of work (e.g. window jobs are compared with window jobs, remodels with remodels). Based on 16 permits (16 STREAM).

Sub-scores

Inspections48
typical
Failed / re-inspection results on 14% of inspections vs 13% expected for similar jobs
Plan quality / Revisions44
worse than peers
1.71 plan send-backs / revision events per permit vs 1.26 expected for similar jobs
Time to permit42
worse than peers
Median 38.5 days to approval vs 18.5 days peer median (1.62× after adjusting for kind of work)
Completion42
worse than peers
19% of issued permits expired/voided without final vs 12% expected
More: compliance & reliability
Compliance49
typical
0.08 license/insurance/stop-work type holds per permit vs 0.07 expected
Reliability62
better than peers
2% of inspections cancelled vs 5% expected

Ann Arbor activity & plain stats

Permits in scored set
16
Last 3 years
9
Last 12 months
2
Years active
5
2022–2026
Median days to approval
38.5
peer median 18.5
Permits needing a revision
75%
Permits with a failed / re-inspection
38%
Inspections on record
48

Job mix

Kinds of work across all 16 permits. Each permit is scored against peers doing the same kind of work.

Remodels 38% (6)Additions / ADUs 25% (4)Decks & porches 25% (4)Windows & doors 6% (1)New homes 6% (1)

Sample permit records

A sample of the public records behind this card. Links open the city's permit portals.

PermitKind of workAppliedStatusDays to approvalNotes
BLDGR24-2518New homes2024-12-03Expired190inspection Compaction [BLD]: Re-inspection required
plan submittal v1 requires re-submit
plan submittal v2 requires re-submit
plan submittal v3 requires re-submit
6 eReview file(s) sent back for resubmittal
Permit placed on hold for more information
BLDGR22-3155Remodels2022-09-01Expired63plan submittal v2 requires re-submit
plan submittal v1 requires re-submit
2 eReview file(s) sent back for resubmittal
permit expired without final
BLDGR24-0406Additions / ADUs2024-02-26Final98inspection Compaction [BLD]: Partial Pass
inspection Footing [BLD]: Partial Pass
inspection Insulation [BLD]: Partial Pass
inspection Rough-In [BLD]: Partial Pass
plan submittal v1 requires re-submit
1 eReview file(s) sent back for resubmittal
BLDGR22-3688Additions / ADUs2022-11-21Void51—
BLDGR22-2147Remodels2022-04-19Final18—
BLDGR25-0494Decks & porches2025-04-02Void - Wrong Workclass——

Related Mixed / general firms

See all ratings · How scores work

Scores update as new permit activity lands. Not a recommendation to hire. Report an error.