50
90% range 47.3–52.5

Renaissance Restorations Inc

General Contractor · Birmingham, MI · #285 of 440 listed overall
Primary kind of workAdditions / ADUs78% of all permits · #12 of 20 additions / adus specialists
activemedium confidence

Overall score: 50 = peer average for the same role and the same kind of work (e.g. window jobs are compared with window jobs, remodels with remodels). Based on 9 permits (3 STREAM + 6 A2Trak).

Sub-scores

Inspections48
typical
Failed / re-inspection results on 22% of inspections vs 18% expected for similar jobs
Plan quality / Revisions42
worse than peers
2.33 plan send-backs / revision events per permit vs 1.32 expected for similar jobs
Time to permit44
worse than peers
Median 59.5 days to approval vs 17 days peer median (1.75× after adjusting for kind of work)
Completion—
not enough data
More: compliance & reliability
Compliance64
better than peers
0.00 license/insurance/stop-work type holds per permit vs 0.04 expected
Reliability69
better than peers
0% of inspections cancelled vs 7% expected

Ann Arbor activity & plain stats

Permits in scored set
9
Last 3 years
3
Last 12 months
2
Years active
6
2013–2026
Median days to approval
59.5
peer median 17.0
Permits needing a revision
67%
Permits with a failed / re-inspection
56%
Inspections on record
32

Job mix

Kinds of work across all 9 permits. Each permit is scored against peers doing the same kind of work.

Additions / ADUs 78% (7)Roofing 11% (1)Commercial alterations 11% (1)

Sample permit records

A sample of the public records behind this card. Links open the city's permit portals.

PermitKind of workAppliedStatusDays to approvalNotes
BLDGR26-0923Additions / ADUs2026-06-09Issued94plan submittal v2 requires re-submit
plan submittal v3 requires re-submit
plan submittal v1 requires re-submit
13 eReview file(s) sent back for resubmittal
Permit placed on hold for more information
BLDGR24-1780Additions / ADUs2024-08-02Final55inspection Final [BLD]: Partial Pass
inspection Insulation [BLD]: Re-inspection required
plan submittal v1 requires re-submit
1 eReview file(s) sent back for resubmittal
Permit placed on hold for more information
BLDG18-2486Additions / ADUs2018-11-29FINALED64inspection **FINAL: FAILED
inspection INSULATION: PARTIAL PASS
review HISTORIC REVIEW: DENIED
revision review: 1ST SUBMITTAL
revision review: APPROVED
BLDG19-0071Additions / ADUs2019-01-15FINALED92inspection INSULATION: PARTIAL PASS
inspection ROUGH: FAILED
BLDG13-0104Roofing2013-01-23EXPIRED0permit expired without final
BLDG21-0409Additions / ADUs2021-02-25FINALED6—