45C
90% range 40.1–52.7
Jazer Construction Company LLC
Primary kind of workMixed / general
occasionalmedium confidence
Sub-scores
Inspections36
worse than peers
Failed / re-inspection results on 28% of inspections vs 13% expected for similar jobs
Plan quality / Revisions48
typical
1.44 plan send-backs / revision events per permit vs 1.23 expected for similar jobs
Time to permit48
typical
Median 17 days to approval vs 18.5 days peer median (1.13× after adjusting for kind of work)
Completion39
worse than peers
30% of issued permits expired/voided without final vs 14% expected
More: compliance & reliability
Compliance57
better than peers
0.03 license/insurance/stop-work type holds per permit vs 0.06 expected
Reliability47
typical
7% of inspections cancelled vs 6% expected
Ann Arbor activity & plain stats
Permits in scored set
8
Last 3 years
5
Last 12 months
0
Years active
2
2023–2024
Median days to approval
17.0
peer median 18.5
Permits needing a revision
75%
Permits with a failed / re-inspection
50%
Inspections on record
39
Job mix
Additions / ADUs 38% Remodels 25% Foundation / structural 12% Windows & doors 12% Decks & porches 12%
Sample permit records
| Permit | Kind of work | Applied | Status | Days to approval | Notes |
|---|---|---|---|---|---|
| BLDGR23-2069 | Additions / ADUs | 2023-10-16 | Final | 23 | inspection Final [BLD]: Re-inspection required inspection Insulation [BLD]: Re-inspection required plan submittal v2 requires re-submit plan submittal v1 requires re-submit |
| BLDGR23-0228 | Remodels | 2023-02-09 | Final | 295 | inspection Rough-In [BLD]: Re-inspection required plan submittal v1 requires re-submit plan submittal v2 requires re-submit 2 eReview file(s) sent back for resubmittal Permit placed on hold for more information |
| BLDGR24-0026 | Additions / ADUs | 2024-01-04 | Final | 79 | inspection Insulation [BLD]: Re-inspection required inspection Rough-In [BLD]: Re-inspection required plan submittal v1 requires re-submit 1 eReview file(s) sent back for resubmittal Permit placed on hold for more information |
| BLDGR23-2155 | Windows & doors | 2023-10-31 | Final | 12 | Permit placed on hold for more information |
| BLDGR24-0992 | Remodels | 2024-04-29 | Withdrawn | 17 | 1 eReview file(s) sent back for resubmittal |
| BLDGR24-0172 | Foundation / structural | 2024-01-30 | Final | 2 | — |
Related Mixed / general firms
45C
Perry Marvin R
Mixed / general work
occasionalhigh confidence
45C
Peter Deininger
Mixed / general work
activefeaturedhigh confidence
44C−
Magoon Cameron Shawn
Mixed / general work
occasionalhigh confidence
44C−
THOMAS BROTHERS PAINTING
Mixed / general work
occasionallow confidence
46C
Volta Homes, LLC
Mixed / general work
activefeaturedmedium confidence